EVM892
29.04.2010 ©Velleman nv
12
The display will show the temperature.
Note: without the thermocouple in place, the display will show the ambient
temperature.
Measuring frequencies
Do not perform frequency measurements in circuits with voltages
> 250V.
Always be careful when working with voltages above 60Vdc or 30Vac rms.
Keep your fingers behind the probe barriers at all times during
measu
r
ement.
Connect the black test lead to the "COM" jack and the red test lead to the
"VHz" jack.
Select the "20KHz" range with the FUNCTION switch.
Connect the test leads to the circuit under test.
Read the measured value from the display.
Notes:
Use a shielded cable for measuring small signals in a noisy environment (min.
visible amplitude: 0.7Vpp).
10. Specifications
This device is not calibrated when purchased!
Regulations concerning environment of use:
Use this meter only for measurements in CAT I and CAT II environments (see
§4)
Use this meter only in a pollution degree 2 environment (see §5)
Ideal temperature 23°C
Ideal relative humidity 75%
Max. altitude 2000m
Overvoltage/installation category 600V CAT. II
Pollution degree Pollution degree 2
Max. voltage between terminal and
earth
600VDC or 600Vrms AC (sine wave)
Display 3 ½ digit LCD, 2 to 3 readings/sec.
Fuse protection 200mA-range: F 0.2A/250V resettable
10A-range: ceramic F10A/250V
Power supply 9V-battery 6LF22 (only use non-
rechargeable batteries)
Ranging method manual
Polarity indication " - " is displayed
Overrange indication " 1. " is displayed automatically
Battery-low indication
" " is displayed
Operating temperature 0°C to 40°C
Storage temperature -10°C to 50°C
Dimensions 88 x 170 x 38mm
Weight 340g (incl. battery)