Available commands:
Command
Description Parameter
‘E’ Emergency stop Don’t care (anything goes)
‘D’ Display address on all digits Don’t care
‘B’ Byte-command 0..255 (see drawing)
‘S’ Strobe command Don’t care
‘C’ Change address 0..255 (new address)
‘R’ Reset all displays Don’t care
‘F’ Force address Don’t care
‘A Send ASCII 32,48..57 (blank, 0..9)
‘P’ Decimal point 0 or 255 (OFF / ON)
‘I’ Intensity control 0 or 255 (BRIGHT / DIM)
‘E’ : Emergency stop. All displays are blanked, regardless of address.
(Hint : execute the ‘Strobe’ command to restore all displays)
‘D’ : Display address all digits. All digits show their address. Addresses between 0 and 9 are displayed
as 0 to 9
Addresses between 10 and 19 are displayed as 0. to 9. (See earlier). Addresses between 20 and 255
are displayed in a binary fashion (see drawing).
Hook-up